-40%

USA! 1 PC 12 VDC PLC CYCLE TIMER MULTIFUNCTION DELAY MODULE MANY SETTINGS !!

$ 7.52

Availability: 365 in stock
  • Coil Voltage Rating: 12 VDC
  • Power Rating (VA): 10 AMP
  • Coil Voltage: 12 VDC
  • Current Rating: 10 AMPS
  • Refund will be given as: Money Back
  • Condition: New
  • All returns accepted: Returns Accepted
  • MPN: 12 VDC 10 AMP RELAY
  • Brand: GENERIC SUPPLIER
  • Control Voltage: 12 VDC
  • Return shipping will be paid by: Buyer
  • Contact Current Rating: SILVER
  • Item must be returned within: 30 Days

    Description

    HELLO , I FIGURED OUT HOW TO SET THESE UP FOR TENTHS OF A SECONDS INTERVALS ,
    , I WILL SHIP MORE THAN ONE IN A WHITE BOX ,
    IF YOU NEED THIS TO DO A CERTAIN TASK , MESSAGE ME TO MAKE SURE IT WILL DO WHAT YOU WANT .
    1 PC OF A 12VDC PLC MULTIFUNCTION PROGRAMMABLE 10 AMP RELAY BOARD ,
    A VERY IMPRESSIVE PRODUCT, MANY MANY FEATURES  , STILL A LOT OF GOOD FUNCTIONS , WITH AND WITHOUT , HIGH SIGNAL NEEDED .
    HAS SOME FUNCTIONS THAT ARE CYCLE RELAY ON FOR ADJUSTABLE TIME , THEN OFF FOR ADJUSTABLE TIME  , THEN REPEATS ,
    OR CAN SET TO RECEIVE ANOTHER HIGH PULSE BEFORE REPEATING SET TIMES , NICE !  , PLEASE ASK IF WHAT YOU WOULD NEED IT TO DO , IS POSSIBLE .
    I WILL SET ONE UP FOR YOUR RECOMMENDATION TO ENSURE THE FEATURE WILL WORK !! , SHIPS OUT SAME DAY OR WITHIN 24 HOURS OF CLEARED PAYMENT NEXT WORKING DAY , USPS MAIL
    Tips: Functional 1-8 on power-up self-start function 9-18 require high pulse signal (high-level duration of not less than 20ms, hereinafter the same) trigger the start.
    Function 1:
    Timing pull: After power, time delay relay T1, T1 between 1 second -270 hours adjustable, to a high level pulse signal CH1 interfaces, repeat the above functions;
    Function 2:
    Timing off: when the power relay, the relay off delay time T1, T1 between 1 second -270 hours adjustable, to a high level pulse signal CH1 interfaces, repeat the above functions;
    Function 3:
    Timing pull off again: After power relay to not pull the delay time T1 reaches the relay; time relay pull off T2 after arrival, the delay time T1 and T2 in 1 second -270 hours
    adjustable from an interface to CH1
    High-level pulse signal, repeat the above functions;
    Function 4:
    And then pull off the timing: after power relay immediately pull off the relay after the delay time T1 arrival; off time T2 after arrival relay in 1 second -270 hours of delay time between T1 and T2
    adjustable to a high level pulse signal CH1 interfaces, repeat the above functions;
    Function 5:
    Infinite loop timing mode 1: after power relay to not pull the delay time T1 arrives relay; time relay pull off after T2 arrive, and then repeat the above state, the delay time T1 and T2 in 1
    Adjustable between seconds -270 hours, to a high pulse signal CH1 interface, we can resume these functions;
    Function 6:
    Infinite Loop Timing Mode 2: After power, the relay immediately pull, delay time T1 reaches the relay off; off time T2 after arrival relay, and then repeat the above state, the delay time T1 and T2 in 1 second
    Adjustable between -270 hours, to a high pulse signal CH1 interface, you can resume these functions;
    Function 7:
    Finite loop timing mode 1: 5 on the basis of function, increase of the cycle function, this time between T1 and T2 in 1 second -9999 seconds adjustable, the number of cycles between NX 1-9999 times available to CH1 interfaces
    a high level pulse signal, we can resume these functions;
    Function 8:
    Finite Loop Timing Mode 2: 6 on the basis of the function, number of cycles increases function, this time between T1 and T2 in 1 second -9999 seconds adjustable, the number of cycles between NX 1-9999 times available to CH1 interfaces
    a high level pulse signal, we can resume these functions;
    Function 9:
    Latching relay modes: CH1 interfaces to relay a high level pulse signal, relay, to give a high pulse signal relay switches off.
    Function 10:
    Trigger relay modes: CH1 interfaces to relay a high-level signal, relay, high disappear, the relay off.
    Function 11:
    Pull the trigger timing: after power relay does not act, CH1 interfaces to a high level pulse signal, the delay time relay T1, T1 at -270 hours adjustable between 1 second and repeat a high-level interfaces to CH1
    pulse signal, repeat the above function;
    Function 12:
    Disconnect trigger timing: after power relay does not act, to a high level pulse signal CH1 interfaces, relay, relay off delay time T1, T1 at -270 hours adjustable between 1 second and repeat for CH1 Interface
    a high level pulse signal, repeat the above functions;
    Features 13:
    Pull the trigger timing and then disconnect: After power relay does not act, the interface to a high-level pulse signal CH1, the delay time T1 arrives relay; time relay pull off after T2 arrival, the delay time T1 and
    T2 at -270 hours adjustable between 1 second and repeat for a high level pulse signal CH1 interfaces, repeat the above functions;
    Function 14:
    Disconnect and then pull the trigger timing: after power relay does not act, the interface to a high-level pulse signal CH1, immediately pull the relay, the relay off delay time T1 after arrival; off time T2 after arrival relay,
    Delay times T1 and T2 at -270 hours adjustable between 1 second and repeat for a high level pulse signal CH1 interfaces, repeat the above functions;
    Function 15:
    Infinite Loop Timing Mode 1: After power relay does not act, to a high pulse signal CH1 interfaces, the delay time T1 arrives relay; pull off the relay arrival time T2, then repeat the above state, the extension
    When the time T1 and T2 at -270 hours adjustable between 1 second and repeat CH1 interfaces to a high level pulse signal, we can resume these functions;
    Function 16:
    Infinite Loop Timing Mode 2: After power relay does not act, the interface to a high-level pulse signal CH1, immediately pull the relay, the relay off delay time T1 after arrival; off-time T2 after reaching relay, then
    Repeat the above state, the delay time between T1 and T2 in 1 second -270 hours adjustable, repeat CH1 interfaces to a high level pulse signal, we can resume these functions;
    Features 17:
    Finite Loop Timing Mode 1: 15 on the basis of features, increase the number of cycles function, this time between T1 and T2 in 1 second -9999 seconds adjustable, NX cycles adjustable between 1-9999 times, repeat to CH1
    interface to a high-level pulse signal, we can resume these functions;
    Function 18:
    Finite Loop Timing Mode 2: On the basis of function 16 on the increase in the number of cycles function, this time between T1 and T2 in 1 second -9999 seconds adjustable, NX cycles adjustable between 1-9999 times, repeat to CH1
    interface to a high-level pulse signal, you can restart the above functions.
    Package Included:
    1 x DC 12V Multifunction Self-lock Relay PLC Cycle Timer Module Delay Time Switch
    SETTING INSTRUCTIONS ; THESE ARE VERY MUCH LIKE SETTING AN OLD DIGITAL WATCH , JUST PRESS THE SET BUTTON UNTIL THE DISPLAY FLASHES , IT STARTS WITH THE LED BLINKING BESIDE THE "MD"= MODE , USE THE NUM- & NUM+ BUTTONS TO ADJUST IT UP OR DOWN , ALSO THE "SWI" BUTTON WILL CHANGE THE DISPLAY SETTING TO THE NEXT DIGIT , AFTER SETTING THE MODE , PRESS THE SET BUTTON AGAIN THIS STORES THE MODE AND INCREMENTS THE DISPLAY TO SET THE "T1"= TIMER 1 , IT TOO ADJUSTS WITH THE NUM- & NUM+ BUTTONS AND THE "SWI" BUTTON, CHANGES THE DIGITS TO BE ADJUSTED , WHEN FINISHED PRESS THE SET BUTTON AGAIN , IT SAVES AND INCREMENTS TO THE "T2"= TIMER 2 , REPEAT THE SAME FOR THIS ALSO AND WHEN FINISHED PRESS "SET" , IT WILL THEN INCREMENT TO THE "NX"= INTERNAL CLOCK , THIS FEATURE WILL CHANGE THE TIMING METHOD AND SHOULD BE LEFT ALONE  ( THE DEFAULT FOR SECONDS IS 101 )  PRESS AND HOLD SET AGAIN , ALL FINISHED !! , THE BOARD WILL START THE SETTINGS YOU HAVE SET , SOME MODES REQUIRE A +12VDC INPUT TO RESTART , AND SOME MODES DO NOT .
    Package:
    1 PC OF A 12 VDC PLC , 4 KEY , PROGRAMMABLE TIMER RELAY 1-9999 SECONDS DELAY ON AND OFF TIMES